Open Access
Table 2.
Forecast performance results in terms of POD, FAR and average warning time of the UMASEP scheme (WCP model only) using microwave and soft X-ray (SXR) data from 2011 December 01 to 2012 December 31.
UMASEP-10mw |
UMASEP-10 |
||
---|---|---|---|
(5 GHz) | (9 GHz) | (SXR) | |
Probability of detection | 77.8% (7/9) | 77.8% (7/9) | 77.8% (7/9) |
False-alarm ratio | 0% (0/7) | 0% (0/7) | 12.5% (1/8) |
Average warning time | 30.7 min | 30.7 min | 26.4 min |