Open Access
Table 1
Autoscaling results of the oblique ionograms data set of 576 ionograms recorded between May 2, 2015 and May 24, 2015. Accurate cases (ǀMUFOISA−MUFOperatorǀ≤0.5 MHz) are a subset of acceptable cases (ǀMUFOISA−MUFOperatorǀ≤1.5 MHz).
Scaled by OIASA | Discarded by OIASA | |||
---|---|---|---|---|
No. of cases | % | No. of cases | % | |
The Operator did not scale the MUF | 22 | 4.0 | 14 | 77.8 |
The operator scaled the MUF | 536 | 96.0 | 4 | 22.2 |
Total | 558 | – | 18 | – |
Scaled by OIASA and the operator | ||
---|---|---|
No. of cases | % | |
Accurate | 166 | 31.0 |
Acceptable (including accurate) | 367 | 68.5 |
Poor | 169 | 31.5 |
Total | 536 | – |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.