Open Access

Table A1

Example of energy limits to identify the incident particle type for one OSM. The energies are expressed in keV. The suffix “l” or “u” means lower or upper limit, respectively. The bold numbers highlight the values that have been used in Figures A1A4.

Threshold energy to trigger a sensor
S1_F S1_S S2 D1 D2 D3

30
30
65
65
65
65



Energy limits in S1 if a valid pattern has been detected
Pattern S2 hit D1 hit D2 hit D3 hit
S1_F_l S1_F_u S1_F_l S1_F_u S1_F_l S1_F_u S1_F_l S1_F_u
Electron 30 100 30 100 30 100 30 100
Proton 400 4000 300 1000 200 800 65 630
S1_S_l S1_S_u S1_S_l S1_S_u S1_S_l S1_S_u S1_S_l S1_S_u
Electron 30 100 30 100 30 100 30 100
Proton 400 4000 300 1000 200 800 65 630

Energy limits in S2, D1, D2, and D3 for a given pattern

S2_l
S2_u
D1_l
D1_u
D2_l
D2_u
D3_l
D3_u
S2 hit, electron 200 3200
D1 hit, electron 400 4000 250 5600
D2 hit, electron 500 3000 400 6300 300 5000
D3 hit, electron 600 2700 500 2500 400 3300 400 2500
S2 hit, proton 3200 25000
D1 hit, proton 8000 25000 7000 25000
D2 hit, proton 6000 15000 7500 25000 8000 25000
D3 hit, proton
1500
10000
1500
12500
1400
20000
1300
25000

Total deposited energy for a given pattern
Pattern S2 hit D1 hit D2 hit D3 hit
S2_l S2_u D1_l D1_u D2_l D2_u D3_l D3_u
Electron 250 3200 1000 6000 1500 10000 2500 4000
Proton 4000 30000 15000 50000 25000 65000 6300 63000

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.