Optical specifications of C1 and C2.
C1 (mm) | C2 (mm) | |
---|---|---|
Aperture of O1 | 200 | 200 |
Focal length of O1 | 2456 | 2488 |
Distance O1 – LM | 2456 | 2488 |
Distance LM – O2 | 56.5 | 56.5 |
Focal length of O2 | 300 | 300 |
Distance O2 – LS | 341 | 340 |
Aperture of LS | 22 | 20 |
Distance LS – O3 | 68 | 68 |
Focal length of O3 | 486 | 500 |
Distance O3 – F | 60 | 40 |
Distance F – O4 | 60 | 40 |
Focal length of O4 | 200 | 200 |
Distance O4 – camera | 200 | 195 |
Focal length of the whole instrument | 1244 | 1133 |