EUVS-C measurement requirements.

Parameter Value Comments
Spectral resolution 0.1 nm Resolve emission cores
Spectral sampling 0.02 nm 5 samples per resolution element
Wavelength coverage 275–284.5 nm Capture full range of the SBUV index
Field of view > 40 arc minutes circular 2° × 2° Nominal design
Cadence 1 minute or less Capture Mg II index variability on 10-minute time scales
Radiometric precision SNR > 150 average @ 277 nm Measure index with 0.1% precision
Detector radiation exposure < 15 krad over mission lifetime Tungsten and aluminum shielding